text.skipToContent text.skipToNavigation

Angio Power Supply 2300475-2-H

2300475-2-H
Used
Interventional Image Guided Systems
GE HealthCare
GE HealthCare
GE HealthCare
N/A
Exchange - Return Defective

Core Exchange
The purchase price for this item is expressly conditioned upon Customer’s return of the corresponding core item to GE HealthCare within 30 days following the shipment date of this item. If GE HealthCare does not receive the core item within such 30 days, GE HealthCare may invoice Customer for the full list price for this item. The core item must be returned in a condition suitable for use, remanufacturing, or refurbishment, as reasonably determined by GE HealthCare in its sole discretion. If the core item is not returned in such condition, GE HealthCare may invoice Customer for the full list price for this item. Customer is responsible for all costs and risks associated with shipping the core item to GE HealthCare.

Add to Wish List
Sign In & Add To Cart
Sign In & Add To Cart
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Field Replaceable Unit (FRU)
  • 230 VAC or 120VAC Input at 50/60 Hz
  • Low Ripple and Stable Output
  • Adjustable Outputs through Potentiometers

Other Buying Options


Condition: New

Product Overview

The Angio Power Supply is a detector power supply system which is being used in an X-ray system. This detector power supply is referred to as the “DPU”. This assembly is being used in the Angio Detector sub-assemblies. The power supply consists of a readily available front end and a Power Supply Control Board (PSCB). The DPU is powered from either 230 VAC or 120VAC at 50/60 Hz and deliver nominal DC output voltages of 19.2, -24.4, 7.35, 6.25, -5.25 Volts. The front-end is basically an AC-DC converter that has multiple DC outputs. There are 5 different supplies, which make up the DPU. There are three connectors to/from the DPU and three connectors are AC line Power to the DPU, Power to the detector, Status / Control of the DPU to the X-ray External Controller. All normally exposed surfaces of ferrous materials are protected against rust or corrosion and wiring is twisted to reduce susceptibility of the supply to external EMI. This power supply assembly is compatible to be used with Discovery IGS 530, Discovery IGS 540 and Discovery IGS 730 Interventional Image Guided Systems. 2300475-2-H

  • Additional Features

    • High efficiency
    • Multiple outputs
    • Wide Operating Temperature
    • Nickel Plated Mounting Plate

    Return And Exchange

    GE HealthCare will accept Customer-returned items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from Customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee), Customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage. Please note, cuffs, BP items, clinical accessories, sterile and hazmat items cannot be returned. If a replacement order is requested, the restocking fee may be waived at GE HealthCare’s sole discretion. 

    • My Recently Viewed Items
      ‹ ›